FLUKE Products |
Since its founding in 1948, Fluke has helped define and grow a unique technology market, providing testing and troubleshooting capabilities that have grown to mission critical status in manufacturing and service industries. Every new manufacturing plant, office, hospital, or facility built today represents another potential customer for Fluke products. From industrial electronic installation, maintenance and service, to precision measurement and quality control, Fluke tools help keep business and industry around the globe up and running. Typical customers and users include technicians, engineers, metrologists, medical-device manufacturers, and computer network professionals ? people who stake their reputations on their tools, and use tools to help extend their personal power and abilities. Fluke has achieved the number one or number two position in every market in which it competes. The Fluke brand has a reputation for portability, ruggedness, safety, ease of use and rigid standards of quality. A wholly owned subsidiary of Danaher Corporation (NYSE:DHR), Fluke is a multi-national corporation headquartered in Everett, Washington, USA. |
LCD display | 6000 |
---|---|
Range selection | automatic/manual |
DC voltage | 600 V ± 0,5% |
AC voltage | 600 V ± 1% |
Resistance | 40 MΩ ± 0,9% |
Continuity test | yes |
Auto power off | yes |
Data hold | yes |
True RMS | yes |
Back light | yes |
Battery indicator | yes |
Dimensions | 167 x 84 x 46 mm |
Guarantee | 36 months |
Manufacturer | Fluke |
LCD display | 6000 |
---|---|
Range selection | automatic/manual |
DC voltage | 600 V ± 0,5% |
AC voltage | 600 V ± 1% |
DC current | 10A ± 1% |
AC current | 10A ± 1,5% |
Resistance | 40 MΩ ± 0,9% |
Capacitance | 10 mF ± 1,9% |
Frequency | 50kHz ± 0,1% |
Continuity test | yes |
Diode test | yes |
Auto power off | yes |
Data hold | yes |
True RMS | yes |
Back light | yes |
Battery indicator | yes |
Dimensions | 167 x 84 x 46 mm |
Guarantee | 36 months |
Manufacturer | Fluke |
LCD display | 6000 |
---|---|
Range selection | automatic/manual |
DC voltage | 600 V ± 0,5% |
AC voltage | 600 V ± 1% |
DC current | 600 µA ± 1% |
AC current | 600 µA ± 1,5% |
Resistance | 40 MΩ ± 0,9% |
Capacitance | 10 mF ± 1,9% |
Frequency | 50kHz ± 0,1% |
Temperature | -40 ÷ 400 °C ± 0,1% |
Continuity test | yes |
Diode test | yes |
Auto power off | yes |
Data hold | yes |
True RMS | yes |
Back light | yes |
Battery indicator | yes |
Dimensions | 167 x 84 x 46 mm |
Guarantee | 36 months |
Manufacturer | Fluke |
LCD display | 6000 |
---|---|
Range selection | automatic/manual |
DC voltage | 600 V ± 0,5% |
AC voltage | 600 V ± 1% |
DC current | 10A ± 1% |
AC current | 10A ± 1,5% |
Resistance | 40 MΩ ± 0,9% |
Capacitance | 10 mF ± 1,9% |
Frequency | 50kHz ± 0,1% |
Continuity test | yes |
Non-contact AC voltage detector | yes |
Diode test | yes |
Auto power off | yes |
Data hold | yes |
True RMS | yes |
Back light | yes |
Battery indicator | yes |
Dimensions | 167 x 84 x 46 mm |
Guarantee | 36 months |
Manufacturer | Fluke |
LCD display | 6000 |
---|---|
Range selection | automatic/manual |
Insulation testing |
range 0,1 MΩ do 2 GΩ, testing voltages 50/100/250/500/1000 V, short-circuit current 1mA, maximum capacitance 1µF |
DC voltage | 1000 V ± 0,09% |
AC voltage | 1000 V ± 2% |
DC current | 400mA ± 0,2% |
AC current | 400mA ± 1,5% |
Resistance | 50 MΩ ± 0,9% |
Capacitance | 10 mF ± 1,2% |
Frequency | 100kHz ± 0,1% |
Continuity test | yes |
Diode test | yes |
Data hold | yes |
True RMS | yes |
Back light | yes |
Battery indicator | yes |
Dimensions | 203 x 100 x 50 mm |
Guarantee | 36 months |
Manufacturer | Fluke |
LCD display | 6000 |
---|---|
Range selection | automatic/manual |
DC voltage |
1000 V ± 0,15%, |
AC voltage | 1000 V ± 1% |
DC current | 10 A ± 1,0% |
AC current | 10 A ± 1,5% |
Resistance | 50 MΩ ± 0,9% |
Capacitance | 10000 µF ± 1,2% |
Frequency | 100 kHz ± 0,1% |
Diode test | yes |
Continuity test | yes |
Auto power off | yes |
Data hold | yes |
True RMS | yes |
Relative measurement | yes |
Back light | no |
Dimensions | 185 x 90 x 43 mm |
Guarantee | lifetime from manufacturer |
Manufacturer | Fluke |
LCD display | 6000 |
---|---|
Range selection | automatic/manual |
DC voltage |
1000 V ± 0,09%, |
AC voltage | 1000 V ± 1% |
DC current | 10 A ± 1,0% |
AC current | 10 A ± 1,5% |
Resistance | 50 MΩ ± 0,9% |
Capacitance | 10000 µF ± 1,2% |
Frequency | 100 kHz ± 0,1% |
Diode test | yes |
Continuity test | yes |
Auto power off | yes |
Data hold | yes |
True RMS | yes |
Relative measurement | yes |
Back light | yes |
Dimensions | 185 x 90 x 43 mm |
Guarante | lifetime from manufacturer |
Manufacturer | Fluke |
LCD display | 6000 |
---|---|
Range selection | automatic/manual |
DC voltage |
1000 V ± 0,09%, |
AC voltage | 1000 V ± 1% |
DC current | 10 A ± 1,0% |
AC current | 10 A ± 1,5% |
Resistance | 50 MΩ ± 0,9% |
Capacitance | 10000 µF ± 1,2% |
Frequency | 100 kHz ± 0,1% |
Temperature | -40 ÷ 400°C ± 1,0% |
Diode test | yes |
Continuity test | yes |
Auto power off | yes |
Data hold | yes |
True RMS | yes |
Relative measurement | yes |
Back light | yes |
Dimensions | 185 x 90 x 43 mm |
Guarantee | lifetime from manufacturer |
Manufacturer | Fluke |
LCD display | 6000 |
---|---|
Range selection | automatic/manual |
True RMS AC | Yes |
Record of measurements | Min/Max/Average |
DC voltage | 0,1 mV do 1000 V ± 0,25% |
AC voltage | 0,1 mV do 1000 V ± 1,0% |
DC current | 1 mA do 10 A ± 1,0% |
AC current | 1 mA do 10 A ± 1,5% |
Resistance | 0,1 Ω do 40 MΩ |
Capacitance | 1 nF do 9999 μF |
Frequency |
5 Hz – 50 kHz (Vac), 45Hz – 50kHz (Aac) |
Temperature | -40°C do +400°C |
Power | AA batteries - Three for main body; two for display |
Battery life | 400h |
Wireless frequency | 2.4 GHz ISM Band 10 meter range |
Protection | Rubber outer layer |
Dimensions | 193 x 53 x 53 mm |
LCD display | 50000 |
---|---|
Range selection | automatic/manual |
DC voltage | 1000 V ± 0,025% |
AC voltage | 1000 V ± 0,4% |
DC current | 10A ± 0,06% |
AC current | 10A ± 0,6% |
Resistance | 500 MΩ ± 0,05% |
Conductance | 50 nS ± 1,0% |
Capacitance | 100 mF ± 1,0%% |
Frequency | 1MHz ± 0,005% |
Temperature | -200 ÷ 1350 °C ± 1,0% |
Continuity test | yes |
Diode test | yes |
Auto power off | yes |
Data hold | yes |
True RMS | yes |
Back light | yes |
Battery indicator | yes |
PC interface | yes |
Dimensions | 203 x 100 x 50 mm |
Guarantee | Unlimited |
Manufacturer | Fluke |
LCD display | 50000 |
---|---|
Range selection | automatic/manual |
DC voltage | 1000 V ± 0,025% |
AC voltage | 1000 V ± 0,4% |
DC current | 10A ± 0,15% |
AC current | 10A ± 0,75% |
Resistance | 500 MΩ ± 0,05% |
Conductance | 500 nS ± 1,0% |
Capacitance | 50 mF ± 1,0% |
Frequency | 1MHz ± 0,005% |
Temperature | -200 ÷ 1350 °C ± 1,0% |
Continuity test | yes |
Diode test | yes |
Auto power off | yes |
Data hold | yes |
True RMS | yes |
Back light | yes |
Battery indicator | yes |
PC interface | yes |
Dimensions | 203 x 100 x 50 mm |
Power | 4 AA batteries (R6) |
Guarantee | Unlimited |
Manufacturer | Fluke |
LCD display | 3200 |
---|---|
Range selection | automatic/manual |
DC voltage | 1000 V ± 0,3% |
AC voltage | 1000 V ± 2,0% |
DC current | 10A ± 1,5% |
AC current | 10A ± 2,5% |
Resistance | 50 MΩ ± 2,5% |
Capacitance | 99,99 µF ± 1,2% |
Frequency | 99,99 kHz ± 0,1% |
Continuity test | yes |
Diode test | yes |
Auto power off | yes |
Data hold | yes |
Back light | yes |
Battery indicator | yes |
Dimensions | 190 x 89 x 45 mm |
Power | 9V battery (6F22) |
Guarantee | Unlimited |
Manufacturer | Fluke |
LCD display | 6000 |
---|---|
Range selection | automatic/manual |
DC voltage | 1000 V ± 0,1% |
AC voltage | 1000 V ± 0,5% |
DC current | 10A ± 0,4% |
AC current | 10A ± 1,2% |
Resistance | 20 MΩ ± 0,4% |
Conductance | 60 nS ± 1,0% |
Capacitance | 10 mF ± 1,0% |
Frequency | 200kHz ± 0,005% |
Continuity test | yes |
Diode test | yes |
Auto power off | yes |
Data hold | yes |
Back light | yes |
Battery indicator | yes |
Dimensions | 200 x 95 x 48 mm |
Power | 9V battery (6F22) |
Guarantee | Unlimited |
Manufacturer | Fluke |
LCD display | 19,999 |
---|---|
Range selection | automatic/manual |
DC voltage | 1000 V ± 0,1% |
AC voltage | 1000 V ± 0,5% |
DC current | 10A ± 0,4% |
AC current | 10A ± 1,2% |
Resistance | 20 MΩ ± 0,4% |
Conductance | 60 nS ± 1,0% |
Capacitance | 10 mF ± 1,0% |
Frequency | 200kHz ± 0,005% |
Temperature | -200 ÷ 1090 °C ± 1,0% |
Continuity test | yes |
Relative measurement | yes |
Diode test | yes |
Auto power off | yes |
Data hold | yes |
True RMS | yes |
Back light | yes |
Battery indicator | yes |
Dimensions | 200 x 95 x 48 mm |
Power | 9V battery (6F22) |
Guarantee | Unlimited |
Manufacturer | Fluke |
Range selection | automatic |
---|---|
AC voltage | 4÷600 V ± 1% |
DC voltage | 4÷1000 V ± 1% |
AC current | 40÷1400 A ± 1,5% |
DC current | 40÷2000 A ± 1,5% |
Resistance | 400 Ω ÷ 400 kΩ ± 1,5% |
Frequency | 5Hz÷1kHz |
True RMS | yes |
Sound signal | yes |
Data hold | yes |
Highlighted LCD | yes |
Battery indicator | yes |
Protection | yes |
Max. clamp set | 58 mm |
Dimensions | 300 x 98 x 52 mm |
Power | 6x AA battery |
Weight | 814g |
Manufacturer | Fluke |
DC current |
4-20 mA ± 0,2%, 10-50 mA ± 1% |
---|---|
Data hold | yes |
Highlighted LCD | yes |
Protection | IP 40 |
Dimensions | 212 x 59 x 38 mm |
Power |
2x AA battery, avarage battery life 20h |
Weight | 260g |
Manufacturer | Fluke |
Range selection | automatic |
---|---|
AC voltage | 600 V ± 1% |
DC voltage | 600 V ± 1% |
AC current | 600 A ± 1% |
DC current | 200 µA ± 1% |
Resistance |
up to 600 Ω ± 1.5%, up to 6000 Ω ± 1.5% |
Frequency | 5÷400 Hz ± 0.5% |
Temperature | -10° - 400°C ± 1% |
Capacitance | 1 - 1000 µF ± 1.9% |
Crest factor |
2.4 @ 500 A, 2.0 @ 600 A |
True RMS | yes |
Sound signal | yes |
Data hold | yes |
Highlighted LCD | yes |
Battery indicator | yes |
Protection | yes |
Max. clamp set | 30 mm |
Dimensions | 38 x 79 x 41 mm |
Power | 2x AA battery |
Weight | 312g |
Manufacturer | Fluke |
AC voltage | 200 - 1000V |
---|---|
Insulation class |
1000 V, CAT IV |
Sound alarm | yes |
Diode alarm | yes |
Power | 2x 1,5V AAA battery |
AC voltage | 90 - 600 V |
---|---|
Insulation class |
600V, CAT IV |
Sound alarm | yes |
Diode alarm |
yes, dual sensitivity |
Power | 1,5V AAA battery |
Max. LCD display | 1000 |
---|---|
Range selection | automatic |
AC voltage | 1000V |
DC voltage | 1000V |
AC current | 100A |
Resistance | 1000Ω |
Continuity test | 0 - 400 Ω |
Dimensions | 203 x 51 x 30,5 mm |
Weight | 380g |
Manufacturer | Fluke |
Max. LCD display | 1000 |
---|---|
Range selection | automatic |
AC voltage | 600V |
DC voltage | 600V |
AC current | 100A |
Resistance | 1000Ω |
Continuity test | 0 - 400 Ω |
Sound signaling | yes |
Dimensions | 203 x 51 x 30,5 mm |
Weight | 380g |
Manufacturer | Fluke |
Transmitter | |
---|---|
Voltage measurement range | 12/50/120/230/400 V |
Frequency range | 0..60 Hz |
Output signal | 125Hz |
Voltage | up to 400V AC/DC |
Power | 6 x 1,5V battery |
Dimmensions | 190 x 85 x 50 mm |
Reciever | |
Tracing depth cable location | 2.5m wall/underground cables |
Main voltage detection | 0.4m |
LCD backlight | yes |
Power | 1 x 9V battery |
Dimmensions | 250 x 65 x 45 mm |
Measurement range | -40 °C ÷ 550 °C ± 1% |
---|---|
Resolution | 0,1 °C |
Field of view | 12÷1 |
Typical distance to target | up to 5m |
Emissirity | regulated 0,3/0,7/0.95 |
Back light | yes |
Other | °C/°F display selection |
Power | 2x AA battery |
Guarante | 24 months |
Manufacturer | Fluke |
Measurement range |
-40 °C ÷ 650 °C ± 1%, K type probe -270 °C ÷ 1372°C ± 2,2 °C ± 1% |
---|---|
Resolution | 0,1 °C |
Field of view | 30÷1 |
Typical distance to target | up to 15m |
Emissivity |
regulated 0,10 ÷ 1,00 with step 0,01, in memory the emissivity table of typical materials |
Back light | yes |
Other | °C/°F display selection |
Memory | 20 measurement results with date and time |
Power | 2x AA battery |
Guarante | 24 months |
Manufacturer | Fluke |
Measurement range | -40 °C ÷ 800 °C ± 1% |
---|---|
Resolution | 0,1 °C |
Field of view | 50÷1 |
Typical distance to target | up to 15m |
Emissirity | regulated 0,10 ÷ 1,00 with step 0,01 |
Back light | yes |
Other | °C/°F display selection |
Memory | 99 measurement results with date and time |
PC interface | yes |
Software | included FLukeView Forms |
Power | 2x AA battery |
Guarante | 24 months |
Manufacturer | Fluke |
Measurement range | -50 °C ÷ 650°C |
---|---|
Resolution | 0.1 °C |
Field of view | 12÷1 |
Emissitivity | adjustable in the range of 0.1 ÷ 1.00 |
Power | AA battery |
Weight | 255g |
DC current | 0-24 mA ± (0,015%+2), |
---|---|
DC voltage | 0-20V ± 0,01%+2), |
Voltage source | 0-100mV and 0-10V |
Loop power supply during mA measurement | 24V |
Dimensions | 201 x 98 x 52 mm |
Power | 9V battery |
Weight | 0,6kg |
Manufacturer | Fluke |
Measurements | |
---|---|
Voltage | 0..30V ± (0,02% + 2 cyfry) |
Current | 0..24mA ± (0,02% + 2 cyfry) |
Resistance | 0..3200Ω |
Thermocouples | J/K/T/E/L/N/U/B/R/S |
RTD |
Ni120 (672), Pt100/200/500/1000 (385), Pt100 (3916), Pt100(3926) |
Source | |
Voltage |
0..10V, max obci±¿enie 1mA |
Voltage mV | -10.00..+75.00 mV |
Resistance | 15..3200Ω |
Thermocouples | J/K/T/E/L/N/U/B/R/S |
RTD |
Ni120 (672), Pt100/200/500/1000 (385), Pt100 (3916), Pt100(3926) |
Other | |
Dimmensions | 200 x 96 x 47 mm |
Power | 6x bateria 1,5V AA (R6) |
Weight | 0,65kg |
Manufacturer | Fluke |
Multimeter | |
---|---|
Range selection | automatic/manual |
DC voltage | 1000 V ± 0,1% |
AC voltage | 1000 V ± 0,5% |
DC current | 30mA ± 0,05% |
AC current | 30mA ± 0,05% |
Resistance | 40 MΩ ± 0,2% |
Frequency | 200kHz ± 0,005% |
Continuity test | yes |
Relative measurement | yes |
Diode test | yes |
True RMS | yes |
Calibrator | |
Current source | 0-20 mA and 4-24 mA ±0,05% of range |
Loop supply | 24V |
Step | auto / manual |
Other | |
PC Interface | yes (infrared) |
Dimensions | 203 x 100 x 50 mm |
Power | 4 x 1,5V AA battery |
Weight | 0,6kg |
Guarantee | 3 lata |
Manufacturer | Fluke |
Measurement range | -40..350°C |
---|---|
Length | 102mm |
Manufacturer | Fluke |
Measurement range | -127 ÷ 600°C |
---|---|
Sensor type | belt |
Manufacturer | Fluke |
Measurement range | -40..1090°C |
---|---|
Length | 213mm |
Manufacturer | Fluke |