PoE: |
| Physical Ports | |
|---|---|
| 10/100/1000 Base-T(X) Ports in RJ45 with P.S.E. Auto MDI/MDIX | 4 |
| 100/1000Base-X SFP Ports | 2 |
| Technology | |
| Ethernet Standards |
IEEE 802.3 for 10BaseT, IEEE 802.3u for 100BaseT(X) and 100BaseFX,, IEEE 802.3z for 1000Base-X, IEEE 802.3x for Flow control, IEEE 802.3at PoE specification (up to 30 Watts per port for P.S.E.) |
| MAC Table | 1024 MAC addresses |
| Processing | Store-and-Forward |
| LED Indicators | |
| Power indicator | Green - Power LED x 2 |
| Fault indicator | Amber - Indicate PWR1 or PWR2 failure |
| 10/100/1000TX RJ45 port Indicator and PoE indicator (P1 ~ P4) |
Green for port Link/Act., Green for PoE power injected |
| 1000X SFP port Indicator (P5 ~ P6) | Green for port Link/Act |
| Fault contact | |
| Relay | Relay output to carry capacity of 1A at 24VDC |
| Power | |
| Input power | Dual DC inputs. 50~57VDC on 6-pin terminal block |
| Power consumption (typical) | 6.3W |
| Overload current protection | present |
| Reverse polarity protection | not present |
| Physical Characteristic | |
| Enclosure | IP-30 |
| Dimension (W x D x H) | 26.1mm x 94.9m x 144.3mm |
| Weight | 410g |
| Environmental | |
| Storage Temperature | -40÷85°C (-40÷185°F) |
| Operating Temperature | -40÷70°C (-40÷185°F) |
| Operating Humidity | 5%÷95% Non-condensing |
| Regulatory approvals | |
| EMI |
FCC Part 15, CISPR (EN55022) class A |
| EMS |
EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge), EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11 |
| Shock | IEC60068-2-27 |
| Free Fall | IEC60068-2-32 |
| Vibration | IEC60068-2-6 |
| Safety | EN60950 |
| Warranty | |
| Warranty period | 5 years |
| Physical Ports | |
|---|---|
| 10/100/1000 Base-T(X) Ports in RJ45 Auto MDI/MDIX with PoE (PSE) | 4 |
| 10/100/1000 Base-T(X) Ports in RJ45 Auto MDI/MDIX | 1 |
| 100/1000Base-X SFP port | 1 |
| Technology | |
| Ethernet Standards |
IEEE 802.3 for 10BaseT, IEEE 802.3u for 100BaseT(X), IEEE 802.3ab for 1000Base-T, IEEE 802.3x for Flow control, 802.3at PoE specyfication |
| MAC Table | 1024 MAC addresses |
| Processing | Store-and-Forward |
| LED Indicators | |
| Power indicator | Green - Power LED x 2 |
| Fault indicator | Amber - Indicate PWR1 or PWR2 failure |
| 10/100/1000Base-T(X) RJ45 port indicator and PoE indicator (P1÷P4) |
Green for port Link/Act., Green for power injected |
| 10/100/1000Base-T(X) RJ45 port indicator (P5) |
Green for port Link/Act., Amber for 100Mbps indicator |
| 100/1000Base-X port indicator | Green for port Link/Act. |
| SFP Speed DIP-Switch | |
| DIP-Switch 1/2 | DIP-Switch 1 (ON) and DIP-Switch 2 (ON) - SFP speed setting to 100Mbps DIP-Switch 1 (OFF) and DIP-Switch 2 (OFF) - SFP speed setting to 1000Mbps |
| DIP-Switch | |
| DIP-Switch 1 |
Power-1 failed warning - (ON) enable, (OFF) disable |
| DIP-Switch 2 |
Power-2 failed warning - (ON) enable, (OFF) disable |
| Fault contact | |
| Relay | Relay output to carry capacity of 1A at 24VDC |
| Power | |
| Input power | Dual DC inputs. 50~57VDC on 6-pin terminal block. |
| Power consumption (typical) | 6.2W |
| Overload current protection | present |
| Reverse polarity protection | not present |
| Physical Characteristic | |
| Enclosure | IP-30 |
| Dimension (W x D x H) | 26.1(W) x 94.9(D) x 144.3(H) mm |
| Weight | 407 g |
| Environmental | |
| Storage Temperature | -40÷85°C (-40÷185°F) |
| Operating Temperature | -40÷70°C (-40÷158°F) |
| Operating Humidity | 5%÷95% Non-condensing |
| Regulatory approvals | |
| EMI |
FCC Part 15, CISPR (EN55022) class A |
| EMS |
EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge), EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11 |
| Shock | IEC60068-2-27 |
| Free Fall | IEC60068-2-32 |
| Vibration | IEC60068-2-6 |
| Safety | EN60950 |
| Warranty | |
| Warranty period | 5 years |
| Physical Ports | |
|---|---|
| 10/100/1000 Base-T(X) Ports in RJ45 Auto MDI/MDIX with PoE+ (P.S.E.) | 4 |
| 10/100/1000 Base-T(X) Ports in RJ45 Auto MDI/MDIX | 1 |
| 100/1000Base-X SFP port | 1 |
| Technology | |
| Ethernet Standards |
IEEE 802.3 for 10BaseT, IEEE 802.3u for 100BaseT(X), IEEE 802.3ab for 1000Base-T, IEEE 802.3x for Flow control, 802.3at PoE specyfication |
| MAC Table | 1024 MAC addresses |
| Processing | Store-and-Forward |
| LED Indicators | |
| Power indicator | Green - Power LED x 2 |
| Fault indicator | Amber - Indicate PWR1 or PWR2 failure |
| 10/100/1000Base-T(X) RJ45 port indicator and PoE Indicator (P1÷P4) |
Green for port Link/Act., Green for power injected |
| 10/100/1000Base-T(X) RJ45 port Indicator (P5) |
Green for port Link/Act., Amber for 100Mbps Indicator |
| 100/1000Base-X SFP port indicator | Green for port Link/Act. |
| SFP Speed DIP-Switch | |
| DIP-Switch 1/2 | DIP-Switch 1 (ON) and DIP-Switch 2 (ON) - SFP speed setting to 100Mbps DIP-Switch 1 (OFF) and DIP-Switch 2 (OFF) - SFP speed setting to 1000Mbps |
| DIP-Switch | |
| DIP-Switch 1 |
Power-1 failed warning - (ON) enable, (OFF) disable |
| DIP-Switch 2 |
Power-2 failed warning - (ON) enable, (OFF) disable |
| Fault contact | |
| Relay | Relay output to carry capacity of 1A at 24VDC |
| Power | |
| Input power | Dual DC inputs. 12~36VDC on 6-pin terminal block |
| Power consumption (typical) | 6.5W |
| Overload current protection | present |
| Reverse polarity protection | not present |
| Physical Characteristic | |
| Enclosure | IP-30 |
| Dimension (W x D x H) | 41 (W) x 94.9 (D) x 144.3(H) mm |
| Weight | 580 g |
| Environmental | |
| Storage Temperature | -40÷85°C (-40÷185°F) |
| Operating Temperature | -40÷60°C (-40÷140°F) |
| Operating Humidity | 5%÷95% Non-condensing |
| Regulatory approvals | |
| EMI |
FCC Part 15, CISPR (EN55022) class A |
| EMS |
EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge), EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11 |
| Shock | IEC60068-2-27 |
| Free Fall | IEC60068-2-32 |
| Vibration | IEC60068-2-6 |
| Safety | EN60950-1 |
| Warranty | |
| Warranty period | 5 years |
| Physical Ports | |
|---|---|
| 10/100 Base-T(X) Ports in RJ45 Auto MDI/MDIX | 8 |
| Technology | |
| Ethernet Standards |
IEEE 802.3 for 10BaseT, IEEE 802.3u for 100BaseT(X), IEEE 802.3x for Flow control, 802.3at PoE specyfication |
| MAC Table | 2048 MAC addresses |
| Processing | Store-and-Forward |
| LED Indicators | |
| Power indicator | Green - Power LED x 2 |
| Fault indicator | Amber - Indicate PWR1 or PWR2 failure |
| 10/100TX RJ45 port Indicator |
Green for port Link/Act., Green for PoE power injected |
| Fault contact | |
| Relay | Relay output to carry capacity of 1A at 24VDC |
| Power | |
| Input power | Dual DC inputs. 2x 12~57VDC on 6-pin terminal block |
| Power consumption (typical) | 4.5W |
| Overload current protection | present |
| Reverse polarity protection | not present |
| Physical Characteristic | |
| Enclosure | IP-30 |
| Dimension (W x D x H) | 26.1mm x 94.9m x 144.3mm |
| Weight | 412g |
| Environmental | |
| Storage Temperature | -40÷85°C |
| Operating Temperature | -40÷70°C |
| Operating Humidity | 5%÷95% Non-condensing |
| Regulatory approvals | |
| EMI |
FCC Part 15, CISPR (EN55022) class A |
| EMS |
EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge), EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11 |
| Shock | IEC60068-2-27 |
| Free Fall | IEC60068-2-32 |
| Vibration | IEC60068-2-6 |
| Safety | EN60950-1 |
| Warranty | |
| Warranty period | 5 years |
| Physical Ports | |
|---|---|
| 10/100 Base-T(X) Ports in RJ45 Auto MDI/MDIX | 8 |
| Technology | |
| Ethernet Standards |
IEEE 802.3 for 10BaseT, IEEE 802.3u for 100BaseT(X), IEEE 802.3x for Flow control, 802.3at PoE specyfication |
| MAC Table | 2048 MAC addresses |
| Processing | Store-and-Forward |
| LED Indicators | |
| Power indicator | Green - Power LED x 2 |
| Fault indicator | Amber - Indicate PWR1 or PWR2 failure |
| 10/100TX RJ45 port Indicator |
Green for port Link/Act., Green for PoE power injected |
| Fault contact | |
| Relay | Relay output to carry capacity of 1A at 24VDC |
| Power | |
| Input power | Dual DC inputs. 50VDC on 6-pin terminal block |
| Power consumption (typical) | 4.5W |
| Overload current protection | present |
| Reverse polarity protection | not present |
| Physical Characteristic | |
| Enclosure | IP-30 |
| Dimension (W x D x H) | 26.1mm x 94.9m x 144.3mm |
| Weight | 412g |
| Environmental | |
| Storage Temperature | -40÷85°C |
| Operating Temperature | -40÷70°C |
| Operating Humidity | 5%÷95% Non-condensing |
| Regulatory approvals | |
| EMI |
FCC Part 15, CISPR (EN55022) class A |
| EMS |
EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge), EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11 |
| Shock | IEC60068-2-27 |
| Free Fall | IEC60068-2-32 |
| Vibration | IEC60068-2-6 |
| Safety | EN60950-1 |
| Warranty | |
| Warranty period | 5 years |
| Physical Ports | |
|---|---|
| 10/100/1000 Base-T(X) Ports in RJ45 with P.S.E. Auto MDI/MDIX | 8 |
| 100/1000Base-X SFP Ports | 2 |
| Technology | |
| Ethernet Standards |
IEEE 802.3 for 10BaseT, IEEE 802.3u for 100BaseT(X) and 100BaseFX,, IEEE 802.3z for 1000Base-X, IEEE 802.3x for Flow control, IEEE 802.3af/at PoE specification (up to 30 Watts per port for P.S.E.) |
| MAC Table | 8k MAC addresses |
| Processing | Store-and-Forward |
| Switch Properties |
Switching latency less than 7us, Switching bandwidth 20Gbps |
| Jumbo frame | Up to 9.6K Bytes |
| Packet buffer | 4Mbit |
| LED Indicators | |
| Power indicator | Green - Power LED x 3 |
| Fault indicator | Amber - Indicate power failed even warning |
| 10/100/1000TX RJ45 port Indicator and PoE indicator (P1 ~ P4) |
Green for port Link/Act., Green for PoE power injected |
| 1000X SFP port Indicator | Green for port Link/Act |
| DIP Switch | |
| DIP-Switch 1 |
Power-1 failed warning (ON) enable, (OFF) disable |
| DIP-Switch 2 |
Power-2 failed warning (ON) enable, (OFF) disable |
| DIP-Switch 3 | DIP switch 3 and 4 (ON) SFP speed setting to 100Mbps |
| DIP-Switch 4 | DIP switch 3 and 4 (OFF) SFP speed setting to 1000Mbps(default) |
| Fault contact | |
| Relay | Relay output to carry capacity of 1A at 24VDC |
| Power | |
| Input power | Dual DC inputs. 50-57 VDC on 6-pin terminal block |
| Power consumption (typical) | 11W |
| PoE Power budget | 180W |
| Overload current protection | present |
| Reverse polarity protection | present |
| Physical Characteristic | |
| Enclosure | IP-30 |
| Dimension (W x D x H) | 54.3(W) x 108.3(D) x 145.1(H) mm (2.13x4.26x5.71 inches.) |
| Weight | 889g |
| Environmental | |
| Storage Temperature | -40÷85°C (-40÷185°F) |
| Operating Temperature | -40÷75°C (-40÷167°F) |
| Operating Humidity | 5%÷95% Non-condensing |
| Regulatory approvals | |
| EMC |
EN55032, EN55024(CE EMC), FCC Part 15B, EN61000-3-2, EN61000-3-3 |
| EMI |
CISPR 32, EN55032, FCC Part 15B class A |
| EMS |
IEC 61000-4-2 (ESD), IEC 61000-4-3 (RS), IEC 61000-4-4 (EFT), IEC 61000-4-5 (Surge), IEC 61000-4-6 (CS), IEC 61000-4-8 (PFMF), IEC 61000-4-11 (DIP) |
| Shock | IEC60068-2-27 |
| Free Fall | IEC60068-2-32 |
| Vibration | IEC60068-2-6 |
| Safety | EN60950-1 |
| Warranty | |
| Warranty period | 5 years |
| Physical Ports | |
|---|---|
| 10/100/1000 Base-T(X) Ports in RJ45 with P.S.E. Auto MDI/MDIX | 8 |
| 100/1000Base-X SFP Ports | 2 |
| Technology | |
| Ethernet Standards |
IEEE 802.3 for 10BaseT, IEEE 802.3u for 100BaseT(X) and 100BaseFX,, IEEE 802.3z for 1000Base-X, IEEE 802.3x for Flow control, IEEE 802.3af/at PoE specification (up to 30 Watts per port for P.S.E.) |
| MAC Table | 8k MAC addresses |
| Processing | Store-and-Forward |
| Switch Properties |
Switching latency less than 7us, Switching bandwidth 20Gbps |
| Jumbo frame | Up to 9.6K Bytes |
| Packet buffer | 4Mbit |
| LED Indicators | |
| Power indicator | Green - Power LED x 3 |
| Fault indicator | Amber - Indicate power failed even warning |
| 10/100/1000TX RJ45 port Indicator and PoE indicator (P1 ~ P4) |
Green for port Link/Act., Green for PoE power injected |
| 1000X SFP port Indicator | Green for port Link/Act |
| DIP Switch | |
| DIP-Switch 1 |
Power-1 failed warning (ON) enable, (OFF) disable |
| DIP-Switch 2 |
Power-2 failed warning (ON) enable, (OFF) disable |
| DIP-Switch 3 | DIP switch 3 and 4 (ON) SFP speed setting to 100Mbps |
| DIP-Switch 4 | DIP switch 3 and 4 (OFF) SFP speed setting to 1000Mbps(default) |
| Fault contact | |
| Relay | Relay output to carry capacity of 1A at 24VDC |
| Power | |
| Input power | Dual DC inputs. 12-57 VDC on 6-pin terminal block |
| Power consumption (typical) | 11W |
| PoE Power budget |
60W at 12~24VDC, 120W at 24~57VDC |
| Overload current protection | present |
| Reverse polarity protection | present |
| Physical Characteristic | |
| Enclosure | IP-30 |
| Dimension (W x D x H) | 54.3(W) x 108.3(D) x 145.1(H) mm (2.13x4.26x5.71 inches.) |
| Weight | 916g |
| Environmental | |
| Storage Temperature | -40÷85°C (-40÷185°F) |
| Operating Temperature | -40÷75°C (-40÷167°F) |
| Operating Humidity | 5%÷95% Non-condensing |
| Regulatory approvals | |
| EMC |
EN55032, EN55024(CE EMC), FCC Part 15B, EN61000-3-2, EN61000-3-3 |
| EMI |
CISPR 32, EN55032, FCC Part 15B class A |
| EMS |
IEC 61000-4-2 (ESD), IEC 61000-4-3 (RS), IEC 61000-4-4 (EFT), IEC 61000-4-5 (Surge), IEC 61000-4-6 (CS), IEC 61000-4-8 (PFMF), IEC 61000-4-11 (DIP) |
| Shock | IEC60068-2-27 |
| Free Fall | IEC60068-2-32 |
| Vibration | IEC60068-2-6 |
| Safety | EN60950-1 |
| Warranty | |
| Warranty period | 5 years |
| Physical Ports | |
|---|---|
| 10/100/1000 Base-T(X) Ports in RJ45 Auto MDI/MDIX with PoE (PSE) | 8 |
| Technology | |
| Ethernet Standards |
IEEE 802.3 for 10BaseT, IEEE 802.3u for 100BaseT(X), IEEE 802.3ab for 1000Base-T, IEEE 802.3x for Flow control, 802.3at PoE specyfication |
| MAC Table | 2048 MAC addresses |
| Processing | Store-and-Forward |
| LED Indicators | |
| Power indicator | Green - Power LED x 2 |
| Fault indicator | Amber - Indicate PWR1 or PWR2 failure |
| 10/100/1000TX RJ45 port Indicator |
Green on only for 1000Mbit, Green and Amber on for 100Mbit, Amber on only for 10Mbit |
| Fault contact | |
| Relay | Relay output to carry capacity of 1A at 24VDC |
| Power | |
| Input power | Dual DC inputs. 12~36VDC on 6-pin terminal block. |
| Power consumption (typical) | 7,8W |
| Overload current protection | present |
| Reverse polarity protection | not present |
| Physical Characteristic | |
| Enclosure | IP-30 |
| Dimension (W x D x H) | 41(W) x 94.9(D) x 144.3(H) mm |
| Weight | 452 g |
| Environmental | |
| Storage Temperature | -40÷85°C (-40÷185°F) |
| Operating Temperature | -40÷70°C (-40÷158°F) |
| Operating Humidity | 5%÷95% Non-condensing |
| Regulatory approvals | |
| EMI |
FCC Part 15, CISPR (EN55022) class A |
| EMS |
EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge), EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11 |
| Shock | IEC60068-2-27 |
| Free Fall | IEC60068-2-32 |
| Vibration | IEC60068-2-6 |
| Safety | EN60950 |
| Warranty | |
| Warranty period | 5 years |
| Physical Ports | |
|---|---|
| 10/100/1000 Base-T(X) Ports in RJ45 with P.S.E. Auto MDI/MDIX | 8 |
| Technology | |
| Ethernet Standards |
IEEE 802.3 for 10BaseT, IEEE 802.3u for 100BaseT(X), IEEE 802.3ab for 1000Base-T, IEEE 802.3x for Flow control, 802.3at PoE specyfication |
| MAC Table | 2048 MAC addresses |
| Processing | Store-and-Forward |
| LED Indicators | |
| Power indicator | Green - Power LED x 2 |
| Fault indicator | Amber - Indicate PWR1 or PWR2 failure |
| 10/100/1000TX RJ45 port Indicator |
Green for port Link/Act., Green for PoE power injected |
| Fault contact | |
| Relay | Relay output to carry capacity of 1A at 24VDC |
| Power | |
| Input power | Dual DC inputs. 50VDC on 6-pin terminal block |
| Power consumption (typical) | 8W |
| PoE Power budget | 180W |
| Overload current protection | present |
| Reverse polarity protection | not present |
| Physical Characteristic | |
| Enclosure | IP-30 |
| Dimension (W x D x H) | 26.1mm x 94.9m x 144.3mm |
| Weight | 390g |
| Environmental | |
| Storage Temperature | -40÷85°C |
| Operating Temperature | -40÷70°C |
| Operating Humidity | 5%÷95% Non-condensing |
| Regulatory approvals | |
| EMI |
FCC Part 15, CISPR (EN55022) class A |
| EMS |
EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge), EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11 |
| Shock | IEC60068-2-27 |
| Free Fall | IEC60068-2-32 |
| Vibration | IEC60068-2-6 |
| Safety | EN60950-1 |
| Warranty | |
| Warranty period | 5 years |
| Physical Ports | |
|---|---|
| 10/100/1000 Base-T(X) Ports in RJ45 Auto MDI/MDIX | 22 |
| Gigabit Combo port with 10/100/1000Base-T(X) and 100/1000Base-X SFP ports | 2 |
| 100/1000Base-X with SFP ports | 2 |
| RS-232 Serial Console Port |
RS-232 in DB-9 connector with console cable. 115200bps, 8, N, 1 |
| Technology | |
| Ethernet Standards |
IEEE 802.3 for 10Base-T, IEEE 802.3u for 100Base-TX and 100Base-FX, IEEE 802.3ab for 1000Base-T, IEEE 802.z for 1000Base-X, IEEE 802.3ae for 10Gigabit Ethernet, IEEE 802.3x for Flow control, IEEE 802.3ad for LACP (Link Aggregation Control Protocol ), IEEE 802.1p for COS (Class of Service), IEEE 802.1Q for VLAN Tagging, IEEE 802.1w for RSTP (Rapid Spanning Tree Protocol), IEEE 802.1s for MSTP (Multiple Spanning Tree Protocol), IEEE 802.1x for Authentication, IEEE 802.1AB for LLDP (Link Layer Discovery Protocol) |
| MAC Table | 8192 MAC addresses |
| Priority Queues | 8 |
| Processing | Store-and-Forward |
| Switching latency | 7 µs |
| Switching bandwidth | 52 Gbps |
| IGMP multicast groups | 256 for each VLAN |
| Port rate limiting | User Define |
| Security Features |
Device Binding security feature, Enable/disable ports, MAC based port security, Port based network access control (802.1x), Single 802.1x and Multiple 802.1x, MAC-based authentication, QoS assignment, Guest VLAN, MAC address limit, TACACS+, VLAN (802.1Q ) to segregate and secure network traffic, Radius centralized password management, SNMPv3 encrypted authentication and access security, Https / SSH enhance network security, Web and CLI authentication and authorization, Authorization (15 levels), IP source guard |
| Software Features |
STP/RSTP (IEEE 802.1D/w), Redundant Ring (O-Ring) with recovery time less than 30ms over 250 units, TOS/Diffserv supported, Quality of Service (802.1p) for real-time traffic, VLAN (802.1Q) with VLAN tagging and GVRP supported, IGMP Snooping for multicast filtering, Port configuration, Port status, Port statistics, Port monitoring, Port security |
| Network Redundancy |
O-Ring, Open-Ring, O-Chain, MRP, MSTP(RSTP/STP compatible), Fast Recovery |
| LED Indicators | |
| Power Indicator | Green LED x 3 Power indicator for AC and DC |
| Ring Master indicator | Green - indicates system operated in O-Ring Master mode |
| O-Ring Indicator (Ring) |
Green - Indicates that the system operating in O-Ring mode, Green Blinking - Indicates that the Ring is broken. |
| Fault indicator | Amber - Indicate unexpected event occurred |
| 10/100/1000Base-T(X) RJ45 port indicator |
Green for Link/Act indicator, Dual color LED for speed indicator ~ Green for 1000Mbps / Amber for 100Mbps / Off-light for 10Mbps |
| 100/1000Base-X SFP+ Port Indicator | Green for port Link/Act. |
| Fault Contact | |
| Relay | Relay output to carry capacity of 1A at 24VDC |
| Power | |
| Input power |
100~240VAC with power cord, and dual 48VDC(36~72VDC) power inputs at 6-pin terminal block |
| Power consumption (typical) | 23W |
| Overload current protection | present |
| Reverse Polarity Protection | Present on DC only |
| Physical Characteristic | |
| Dimension (W x D x H) | 431mm x 342mm x 44mm |
| Weight | 4360g |
| Environmental | |
| Storage Temperature | -40÷85°C(-40÷185°F) |
| Operating Temperature | -40 to 75 °C |
| Operating Humidity | 5%÷95% Non-condensing |
| Regulatory approvals | |
| EMI |
FCC Part 15, CISPR (EN55022) class A |
| EMS |
EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge), EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11 |
| Warranty | |
| Warranty period | 5 years |
Page 21 of 23
|