| Technical specifications | |
|---|---|
| Sensitivity | 0,05 - 0,2 db/m |
| Features | |
| Installation | On the bottom there are Ø5mm mounting holes for fastening the smoke sensor to the surface by 4.8×20mm screws or/and bracket and M4 screws. |
| Connection |
Detector's jack RJ-11 is connected to an analog input of any system unit using patch-cable RJ-11. Determination of the sensor's type and connection occur automatically. The monitoring system allows to connect several smoke detectors into a linear circuit. For this purpose each detector has two jacks RJ-11 input and output. The first is connected to an analog input of the system unit using a patch-cable RJ-11, the consequent is connected via patch-cable RJ-11 to an output of the first detector and so on. as one sensor with one address. |
| Supply includes |
Detector, 4-wired cable RJ11 (2m), 2 screws and 2 nuts M4, 2 screws 4.8×20mm, bracket, double sided sticker. |
| Net weight | 290g |
| Dimensions (LHW) | Ø100×45 |
| Max distance | 150m |
| Technical specifications | |
|---|---|
| Operating temperature | -10 ÷ 80°C |
| Accuracy | 1°C |
| Features | |
| Installation | On the bottom there is a ledge with Ø4.5mm and height 1mm and a Ø5mm mounting hole for fastening the sensor using a 4.8×16 mm screw. |
| Connection | Temperature sensor contains RJ-11 jack and is connected to an analog input of a system unit. Determination of type of sensor and connection occur automatically. |
| Supply includes |
Sensor, 4-wired patch cable RJ11 (2m), 4.8×16mm screw, double sided sticker. |
| Net weight | 50g |
| Dimensions (LHW) | 60×18×18mm |
| Max distance | 100m |
| Technical specifications | |
|---|---|
| Measured temperature range | -10 ÷ 80°C |
| Accuracy | ±0.4°C in –10 to 85 °C range |
| Measured humidity range | 0 - 95%RH |
| Accuracy %RH | ± 3% RH in 0 to 80% range |
| Maximum distance from the appliance | 225m |
| Features | |
| Connection |
Sensor's jack RJ-12 is connected to CAN input of any system unit or to a CAN output of another sensor using RJ-12 patch cable. Determination of sensor's type and connection occur automatically. The system enables connecting multiple sensors to a linear layout. For this purpose, each sensor is equipped with two RJ-11 input and output sockets. |
| Net weight | 160g |
| Dimensions | 68 × 47 x 26 mm |
| Technical specifications | |
|---|---|
| Smoke sensitivity | 0,05 - 0,2 db/m |
| Response time | 10 sec |
| Measured temperature range | -10 to +75 °C |
| Accuracy | ±0.4°C in –10 to 85 °C range. |
| Measured humidity range | 0 - 95%. |
| Accuracy %RH | ± 3% RH in range of 0 - 80% |
| Maximum distance from the appliance | 225m |
| Features | |
| Installation | On the bottom there are mounting holes for fastening the smoke sensor to the surface using screws 4.8×20mm or/and bracket and M4 screws. |
| Connection | Sensor's jack RJ-12 is connected to CAN input of any system unit or to a CAN output of another sensor using RJ-11 patch cable. Determination of sensor's type and connection occur automatically. Monitoring system allows connection of up to 40 smoke sensors into a linear circuit. |
| Set includes |
Sensor, 3-wired shielded patch cable RJ11 (2m), bracket, 2 screws and 2 nuts M4, 2 screws 4.8×20mm, double sided sticker. |
| Net weight | 310g |
| Dimensions (LHW) | Ø100×45mm |
| Number of analog ports | 8 |
|---|---|
| Number of CAN ports | 2 |
| Maximum bus length | 225 meters |
| Maximum analog sensor cable length |
50-150 meters, depending on the sensor type |
| Installation | In the lower part of the casing there are Ø 5 mm holes for mounting the module, |
| at a distance of 50 mm and 89 mm from the center. The cable is connected to the connector on the side wall. | |
| Connection | Can be connected via RJ-12 cable to the CAN input of the control unit or another CAN sensor. The module is automatically detected on the first connection. |
| Set includes |
module, CAN cable RJ-12 (2m), 3.5x16mm screws |
| Net weight | 0.6 kg |
| Dimensions (LHW) | 110×68×40 mm |