| [-]remove#06892 |
[-]remove#06669 |
| Media converter 1x RS232 (DB9) + 1x RS-422/485 (TB, 3kV isolated) (ORing ISC-1112-I) |
Power supply 60W 48VDC, DIN TS35 (Mean Well HDR-60-48) |
| Environment |
| Working temperature |
-
|
-30°C ÷ 70°C
|
| Vibration (component) |
-
|
10÷500Hz, 2G 10min./1cycle, 60min. each along X Y Z axes
|
| Environmental |
| Storage Temperature |
-25÷85°C
|
-
|
| Operating Temperature |
-10÷70°C
|
-
|
| Operating Humidity |
5%÷95% Non-condensing
|
-
|
| Input |
| Voltage range |
-
|
85÷264VAC, 120÷370VDC
|
| Efficiency (typ.) |
-
|
91%
|
| LED Indicators |
| Power Indicator |
Green x1
|
-
|
| TxD Indicator |
Green x1
|
-
|
| RxD Indicator |
Green x1
|
-
|
| Others |
| MTBF |
-
|
min. 441500h MIL-HDBK-217F (25°C)
|
| Dimension (W x H x D) |
-
|
52.5mm x 90mm x 5.5mm |
| Output |
| DC Voltage |
-
|
48V
|
| Rated current |
-
|
1.25A
|
| Current Range |
-
|
0÷1.25A
|
| Rated Power |
-
|
60W
|
| Ripple & noise (max.) |
-
|
240mVp-p
|
| Voltage adjustment range |
-
|
43.2÷55.2V
|
| Voltage tolerance |
-
|
±1.0%
|
| Line regulation |
-
|
±1.0%
|
| Load regulation |
-
|
±1.0%
|
| Physical Characteristic |
| Enclosure |
ABS
|
-
|
| Dimension (W x D x H) |
71.2mm x 25.3mm x 100.6mm
|
-
|
| Weight |
130g
|
-
|
| Physical Ports |
| RS-232 Connector |
DB9 (Female)
|
-
|
| RS-422/485 Connector |
10-pin terminal block opto-isolated to 3kV
|
-
|
| RS-232 Signals |
TxD, RxD, GND
|
-
|
| RS-422/485 Signals (RS422) |
TxD+, TxD-, RxD+, RxD-
|
-
|
| RS-422/485 Signals (RS485) |
Data+, Data-, GND
|
-
|
| Baud Rate |
300bps to 115.2Kbps
|
-
|
| Data bit |
5, 6, 7, 8
|
-
|
| Stop bit |
1, 1.5, 2
|
-
|
| Parity |
None, Even, Odd, Space, Mark
|
-
|
| Flow Control |
XON/XOFF (software), Auto Hardware Direction Control for RS-485
|
-
|
| Power |
| Input power |
10÷30VDC on 10-pin terminal block
|
-
|
| Power consumption (typical) |
2.2W
|
-
|
| Protection |
| Overload |
-
|
105%÷160% rated output power, protection type - constant current limiting - recovers automatically
|
| Overvoltage |
-
|
115%÷150%, protection type - shut down & re-power on to recover
|
| Regulatory approvals |
| EMI |
FCC Part 15, CISPR (EN55022) class A
|
-
|
| EMS |
EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge), EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11
|
-
|
| Shock |
IEC60068-2-27
|
-
|
| Free Fall |
IEC60068-2-32
|
-
|
| Vibration |
IEC60068-2-6
|
-
|
| Safety |
EN60950
|
-
|
| Safety & EMC |
| Safety standards |
-
|
UL62368-1, UL508, TUV EN61558-2-16, IEC62368-1, EAC Tp TC 040, BSMI CNS14336-1 approved
|
| Withstand voltage |
-
|
I/P-O/P 4kVAC
|
| EMC Standards |
-
|
EN55032 class B, EN61000-3-2,33, EN61000-6-2, EN61000-4-2,3,4,5,6,8,11, EN61204-3
|
| Warranty |
| Warranty period |
2 years |
-
|
| Net Price |
103,00 EUR |
17,40 EUR |
« return to products list |