Atel Electronics
[-]remove#07918 [-]remove#07912 [-]remove#07655 [-]remove#06879 [-]remove#06629 [-]remove#07674 [-]remove#06733 [-]remove#04467 [-]remove#07648 [-]remove#08160 [-]remove#04462
Managed switch, 24x 10/1000 RJ-45 + 4 1G/10G SFP+ slots, O/Open-Ring <30ms (ORing RGS-R9244GP+) Managed switch, 12x 10/1000 RJ-45 + 2x100/1000 SFP w/DDM, O/Open-Ring <30ms (ORing IGS-9042GP) Managed switch, 8x 10/1000 RJ-45 + 12x100/1000 SFP w/DDM, O/Open-Ring <30ms (ORing IGS-9812GP) Unmanaged switch, 4x 10/1000 RJ-45 + 1x 1000 SFP , slim housing (ORing IGS-1041GPA) Unmanaged switch, 8x 10/100/500/1000 M12 (ORing TGXS-1080-M12) Unmanaged industrial switch, 4x 100/1000 RJ-45 PoE, 1x 100/1000 RJ-45, 1x 1000 SFP (Wave Industrial WO-IS-M2GF4GT-4POE-M) Module, SFP 1x 1000 Mbps LC SM, 20 km (WO-SSL-1213-020K-I) Patch cable S/FTP (PiMF) cat. 6A, 0.25 m, black Smart switch, 5x 10/100 M12, O-Ring <10ms (ORing TES-250-M12) Unmanaged switch, 16x 10/100 RJ-45 (ORing IES-1160) Patch cable FTP cat. 6, 0.25 m, green LSOH
Port - - - - - - 1x 1000 Mbps LC SM - - - -
TX wavelength - - - - - - 1310 nm - - - -
RX wavelength - - - - - - 1310 nm - - - -
Max. distance - - - - - - 20 km - - - -
Cable type - - - - - - 8.3/125, 8.7/125, 9/125, 10/125 µm - - - -
Operating temperature - - - - - - -40°C ÷ 85°C - - - -
Module type - - - - - - SFP - - - -
Cable
Shielding type / cat - - - - - - - S/FTP cat 6A - - FTP cat 6
Cable construction - - - - - - - 4x2x7/0.15Cu + foil AL + oplot + LSOH - - 4x2x7/0.15CCA + foil AL + braid + LSOH
Core diameter / AWG - - - - - - - 26 - - 26
Outer diameter - - - - - - - 4,1 mm,
LSOH
- - 5,8 mm,
LSOH
Connector
RJ45 plug / molded - - - - - - - 8p8c shielded,
gold plated pins
- - 8p8c shielded,
gold plated pins
Impedance 100 Mhz - - - - - - - 100 +/- 5 Ohm - - 100 +/- 5 Ohm
Frequency - - - - - - - 500 MHz - - 250 MHz
Working temperature - - - - - - - 0°C - 60°C - - 0°C - 60°C
RoHS 2011/65/EU - - - - - - - EN IEC 63000 - - EN IEC 63000
Standards - - - - - - - EN 50173-1,
ISO/IEC 11801,
IEC60332-1,
IEC-60603-7-5,
TIA/EIA 568B
- - EN 50173-1,
ISO/IEC 11801,
IEC60332-1,
IEC-60603-7-5,
TIA/EIA 568B
Environmental
Storage Temperature -40÷85°C(-40÷185°F) -40÷85°C(-40÷185°F) -40÷85°C(-40÷185°F) -40÷85°C (-40÷185°F) -40÷85°C (-40÷185°F) -40÷85°C - - -40÷85°C (-40÷185°F) -40÷85°C(-40÷185°F) -
Operating Temperature -20 to 60 °C (-4 to 140°F ) -40÷70°C (-14÷158°F) -40÷70°C (-14÷158°F) -10÷60°C (-40÷158°F) -40÷75°C (-40÷167°F) -40÷85°C - - -40÷70°C (-40÷158°F) -40÷70°C (-40÷158°F) -
Operating Humidity 5%÷95% Non-condensing 5%÷95% Non-condensing 5%÷95% Non-condensing 5%÷95% Non-condensing 5%÷95% Non-condensing 5%÷95% Non-condensing - - 5%÷95% Non-condensing 5%÷95% Non-condensing -
Fault contact
Relay Relay output to carry capacity of 1A at 24VDC Relay output to carry capacity of 1A at 24VDC Relay output to carry capacity of 1A at 24VDC Relay output to carry capacity of 1A at 24VDC Relay output to carry capacity of 3A at 24VDC on M12 connector (5-pin A-coding) - - - - Relay output to carry capacity of 1A at 24VDC -
LED Indicators
Power indicator Green - power indicator - - Green - Power LED x 2 - - - - Green - Power LED x 1,
Indicates power input
Green - Power LED x 3 -
Power / Ready indicator - Green - Ready LED x 3 Green - Ready LED x 2 - Green Power LED x 3 - - - - - -
Fault Indicator Green - System is operating continuously Amber - Indicate unexpected event occurred Amber - Indicate unexpected event occurred Amber - Indicate PWR1 or PWR2 failure Amber Indicate PWR1 or PWR2 failure - - - - Yellow - Indicate PWR1 or PWR2 failure -
10/100/500/1000Base-T(X) M12 port indicator - - - - Top for 10/100/1000Mbps port Link/Act indicator. Green for 1Gbps link,
Amber for 10/100 Mbps link,
Bottom Amber for 500Mbps port Link/Act indicator
- - - - - -
10/100/1000TX RJ45 port Indicator - - - Green on only for 1000Mbit,
Green and Amber on for 100Mbit,
Amber on only for 10Mbit
- - - - - - -
10/100TX RJ45 port indicator - - - - - - - - - Green for port Link/Act,
Yellow for Duplex/Collision
-
1000X SFP port Indicator - - - Green for port Link/Act - - - - - - -
Ready / Ring Master Indicator - - - - - - - - Amber LED - Light on for system ready / Blinking for system ready and Ring master mode - Light off for system failed - -
O-Ring Indicator - Green - Indicate system operated in O-Ring mode Green - Indicate system operated in O-Ring mode - - - - - Amber - Indicates port operating in O-Ring mode (per port) - -
10/100TX Port Indicator - - - - - - - - Green for port Link/Act. (per port) - -
O-Ring Indicator (Ring) Green - Indicates that the system operating in O-Ring mode,
Green Blinking - Indicates that the Ring is broken.
- - - - - - - - - -
Ring Master indicator Green - indicates system operated in O-Ring Master mode Green - Indicate system operated in O-Ring Master mode Green - Indicate system operated in O-Ring Master mode - - - - - - - -
1G/10GBase-X SFP+ Port Indicator Green for port Link/Act. - - - - - - - - - -
10/100/1000Base-T(X) RJ45 port indicator Green for Link/Act indicator,
Dual color LED for speed indicator ~ Green for 1000Mbps / Amber for 100Mbps / Off-light for 10Mbps
Green for port 1000Mbps Link/Act,
Amber for 10/100Mbps Link/Act
Green for port 1000Mbps Link/Act,
Amber for 10/100Mbps Link/Act
- - - - - - - -
100/1000Base-X SFP port Indicator - Green for port Link/Act Green for port Link/Act - - - - - - - -
Physical Characteristic
Dimension (W x H x D) - - - - - 33mm x 115mm x 85mm - - - - -
Enclosure - IP-30 IP-30 IP-30 IP-30 IP-40 - - - IP-30 -
Dimension (W x D x H) 431mm x 342mm x 44mm 74.3mm x 109.2mm x 153.6mm 96.4mm x 105.5mm x 154mm 26.1mm x 94.9m x 144.3mm 125 x 65 x 196 mm - - - 88.9 (W) x 40 (D) x 178.2 (H)mm 74.3mm x 109.2mm x 153.6mm -
Weight 6597g 765g 1210g 403g 812 g 350g - - 375g 1060g -
Physical Ports
10/100/1000 Base-T(X) Ports in RJ45 Auto MDI/MDIX 24 12 8 4 - - - - - - -
10/100/1000 Base-T(X) Auto MDI/MDIX ports - - - - 8 - - - - - -
100/1000 Base-T(X) Ports in RJ45 Auto MDI/MDIX - - - - - 4 w/PoE - - - - -
10/100 Base-T(X) Ports w/Auto MDI/MDIX - - - - - - - - 5 - -
10/100 Base-T(X) Ports in RJ45 Auto MDI/MDIX - - - - - - - - - 16 -
Connector Type - - - - Waterproof M12 - - - Waterproof M12 - -
1000Base-FX SFP ports - - - - - 2 - - - - -
1G/10GBase-X with SFP+ port 4 - - - - - - - - - -
100/1000 Mbps SFP Ports - 2 12 - - - - - - - -
1000Base-X SFP Ports - - - 1 - - - - - - -
RS-232 Serial Console Port RS-232 in RJ45 connector with console cable (115200bps 8 N 1) RS-232 in RJ45 connector with console cable (115200bps 8 N 1) RS-232 in RJ45 connector with console cable (115200bps 8 N 1) - - - - - - - -
Power
Redundant Input Power - - - - Dual 12~48VDC on 5-pin M23 connector,
72~110VDC for TGS-1080-M12-MV
- - - - - -
Input power 100 ~ 240VAC with power cord Dual DC inputs. 12÷48VDC on 6-pin terminal block Dual DC inputs. 12÷48VDC on 6-pin terminal block Dual DC inputs. 12÷48VDC on 6-pin terminal block - - - - 12~ 48 VDC Dual DC inputs. 12÷48VDC on 6-pin terminal block -
Power consumption (typical) 37.4W 12.67W 10W 5.5W 7W - - - 3W 9W -
Overload current protection present present present present present - - - present present -
Reverse Polarity Protection - present present present on terminal block present - - - present present on terminal block -
Connector Type - - - - - - - - Waterproof M12 - -
Regulatory approvals
EMC - - - - CE EMC (EN 55024,
EN 55032),
FCC Part 15B,
EN 50121-3-2 (EN 50155)
- - - - - -
EMI FCC Part 15,
CISPR (EN55022) class A
FCC Part 15,
CISPR (EN55022) class A,
EN50155 (EN50121-3-2,
EN55011,
EN50121-4)
FCC Part 15,
CISPR (EN55022) class A
FCC Part 15,
CISPR (EN55022) class A
EN 55032,
CISPR32,
EN 61000-3-2,
EN 61000-3-3,
FCC Part 15B class A
FCC Part 15,
CISPR (EN55022) class A,
EN50155 (EN50121-3-2,
EN55011,
EN50121-4)
- - FCC Part 15,
CISPR (EN55022) class A,
EN50155 (EN50121-3-2,
EN55011,
EN50121-4)
FCC Part 15,
CISPR (EN55022) class A
-
EMS EN61000-4-2 (ESD),
EN61000-4-3 (RS),
EN61000-4-4 (EFT),
EN61000-4-5 (Surge),
EN61000-4-6 (CS),
EN61000-4-8,
EN61000-4-11
IEC61000-4-2 (ESD),
IEC61000-4-3 (RS),
IEC61000-4-4 (EFT),
IEC61000-4-5 (Surge),
IEC61000-4-6 (CS),
IEC61000-4-8,
IEC61000-4-11
EN61000-4-2 (ESD),
EN61000-4-3 (RS),
EN61000-4-4 (EFT),
EN61000-4-5 (Surge),
EN61000-4-6 (CS),
EN61000-4-8,
EN61000-4-11
EN61000-4-2 (ESD),
EN61000-4-3 (RS),
EN61000-4-4 (EFT),
EN61000-4-5 (Surge),
EN61000-4-6 (CS),
EN61000-4-8,
EN61000-4-11
EN 55024 (IEC/EN 61000-4-2 (ESD),
IEC/EN 61000-4-3 (RS),IEC/EN 61000-4-4 (EFT),
IEC/EN 61000-4-5 (Surge),
IEC/EN 61000-4-6 (CS),
IEC/EN 61000-4-8(PFMF),
IEC/EN 61000-4-11 (DIP))
EN61000-4-2 (ESD),
EN61000-4-3 (RS),
EN61000-4-4 (EFT),
EN61000-4-5 (Surge),
EN61000-4-6 (CS),
EN61000-4-8,
EN61000-4-11
- - EN61000-4-2 (ESD),
EN61000-4-3 (RS),
EN61000-4-4 (EFT),
EN61000-4-5 (Surge),
EN61000-4-6 (CS),
EN61000-4-8,
EN61000-4-11
EN61000-4-2 (ESD),
EN61000-4-3 (RS),
EN61000-4-4 (EFT),
EN61000-4-5 (Surge),
EN61000-4-6 (CS),
EN61000-4-8,
EN61000-4-11
-
Shock - IEC60068-2-27 IEC60068-2-27 IEC60068-2-27 IEC60068-2-27 IEC60068-2-27 - - IEC60068-2-27 IEC60068-2-27 -
Free Fall - IEC60068-2-32 IEC60068-2-32 IEC60068-2-32 IEC60068-2-31 IEC60068-2-32 - - IEC60068-2-32 IEC60068-2-32 -
Vibration - IEC60068-2-6 IEC60068-2-6 IEC60068-2-6 IEC60068-2-6 IEC60068-2-6 - - IEC60068-2-6 IEC60068-2-6 -
Safety - EN60950 EN60950 EN60950 EN60950-1 EN60950-1 - - EN60950-1 EN60950 -
Other - - - - EN50155 - - - - - -
MTBF - - - - 409156 hrs - - - - - -
Technology
Ethernet Standards IEEE 802.3 for 10Base-T,
IEEE 802.3u for 100Base-TX and 100Base-FX,
IEEE 802.3ab for 1000Base-T,
IEEE 802.z for 1000Base-X,
IEEE 802.3ae for 10Gigabit Ethernet,
IEEE 802.3x for Flow control,
IEEE 802.3ad for LACP (Link Aggregation Control Protocol ),
IEE
IEEE 802.3 for 10BaseT,
IEEE 802.3u for 100BaseT(X) and 100BaseFX,
IEEE 802.3z for 1000Base-X,
IEEE 802.3ab for 1000Base-T,
IEEE 802.3x for Flow control,
IEEE 802.3ad for LACP (Link Aggregation Control Protocol),
IEEE 802.1D for STP (Spanning Tree Protoc
IEEE 802.3 for 10BaseT,
IEEE 802.3u for 100BaseT(X) and 100BaseFX,
IEEE 802.3z for 1000Base-X,
IEEE 802.3ab for 1000Base-T,
IEEE 802.3x for Flow control,
IEEE 802.3ad for LACP (Link Aggregation Control Protocol),
IEEE 802.1D for STP (Spanning Tree Protoc
IEEE 802.3 for 10BaseT,
IEEE 802.3u for 100BaseT(X) and 100BaseFX,,
IEEE 802.3z for 1000Base-X,
IEEE 802.3x for Flow control
IEEE 802.3 for 10BaseT,
IEEE 802.3u for 100BaseT(X),
IEEE 802.3x for Flow control,
IEEE 802.3ab for 1000Base-T
IEEE 802.3u for 100Base-TX and 100Base-FX,
IEEE 802.3ab for 1000Base-T,
IEEE 802.3z for 1000Base-X
- - IEEE 802.3 for 10BaseT,
IEEE 802.3u for 100BaseT(X),
IEEE 802.3x for Flow control,
IEEE 802.1D for STP (Spanning Tree Protocol),
IEEE 802.1w for RSTP (Rapid Spanning Tree Protocol),
IEEE 802.1AB for LLDP (Link Layer Discovery Protocol)
IEEE 802.3 for 10BaseT,
IEEE 802.3u for 100BaseT(X),
IEEE 802.3x for Flow control
-
LED Indicators - - - - - power,
RJ45 ports (5)
- - - - -
MAC Table 8192 MAC addresses 8192 MAC addresses 8192 MAC addresses 1024 MAC addresses 4k MAC addresses - - - 2048 MAC addresses 8192 MAC addresses -
Priority Queues 8 8 8 - - - - - 4 - -
Processing Store-and-Forward Store-and-Forward Store-and-Forward Store-and-Forward Store-and-Forward - - - Store-and-Forward Store-and-Forward -
Power - - - - - Dual DC inputs. 48÷57VDC on 4-pin terminal block - - - - -
Power consumption (typical) - - - - - 6.5W - - - - -
Switching bandwidth 128 Gbps 28 Gbps 40 Gbps - - - - - 1.0 Gbps - -
VLAN - - - - - - - - Port Based - -
Switching latency 7 µs 7 µs 7 µs - - - - - - - -
Security Features Device Binding security feature,
Enable/disable ports,
MAC based port security,
Port based network access control (802.1x),
Single 802.1x and Multiple 802.1x,
MAC-based authentication,
QoS assignment,
Guest VLAN,
MAC address limit,
TACACS+,
VLAN (802.1Q
Enable/disable ports,
MAC based port security,
Port based network access control (802.1x),
VLAN (802.1q ) to segregate and secure network traffic,
Radius centralized password management,
SNMPv3 encrypted authentication and access security
Enable/disable ports,
MAC based port security,
Port based network access control (802.1x),
VLAN (802.1q ) to segregate and secure network traffic,
Radius centralized password management,
SNMPv3 encrypted authentication and access security
- - - - - Enable/disable ports,
VLAN to segregate and secure network traffic,
SNMP v3 encrypted authentication and access security
- -
Software Features STP/RSTP (IEEE 802.1D/w),
Redundant Ring (O-Ring) with recovery time less than 30ms over 250 units,
TOS/Diffserv supported,
Quality of Service (802.1p) for real-time traffic,
VLAN (802.1Q) with VLAN tagging and GVRP supported,
IGMP Snooping for multicast
STP/RSTP (IEEE 802.1D/w),
Redundant Ring (O-Ring) with recovery time less than 30ms over 250 units,
TOS/Diffserv supported,
Quality of Service (802.1p) for real-time traffic,
VLAN (802.1Q) with VLAN tagging and GVRP supported,
IGMP Snooping for multicast
STP/RSTP (IEEE 802.1D/w),
Redundant Ring (O-Ring) with recovery time less than 30ms over 250 units,
TOS/Diffserv supported,
Quality of Service (802.1p) for real-time traffic,
VLAN (802.1Q) with VLAN tagging and GVRP supported,
IGMP Snooping for multicast
- - - - - STP/RSTP (IEEE 802.1D/w),
Redundant Ring (O-Ring) with recovery time less than 10ms over 250 units,
Port configuration,
Port status,
Port statistics,
Port monitoring,
Port security
Port configuration,
Port status,
Port statistics,
Port monitoring,
Port security
-
Max. Number of Available VLANs - 256 256 - - - - - - - -
Number of VLAN IDs - VID 1 to 4094 VID 1 to 4094 - - - - - - - -
Network Redundancy O-Ring,
Open-Ring,
O-Chain,
MRP,
MSTP(RSTP/STP compatible),
Fast Recovery
STP,
RSTP,
MSTP,
O-Ring
STP,
RSTP,
MSTP,
O-Ring
- - - - - O-Ring,
Open-Ring,
Fast recovery,
STP,
RSTP
- -
IGMP multicast groups 128 for each VLAN 128 for each VLAN 128 for each VLAN - - - - - - - -
Port rate limiting User Define User Define User Define - - - - - - - -
DDM Function - Voltage,
Current,
Temperature
Voltage,
Current,
Temperature
- - - - - - - -
Warranty
Warranty period 5 years 5 years 5 years 5 years 5 years 5 years - - 5 years 5 years -
Net Price 1 720,00 EUR 981,00 EUR 1 020,00 EUR 180,00 EUR 605,00 EUR 82,80 EUR 8,37 EUR 0,693 EUR Call 416,00 EUR 0,434 EUR

« return to products list